File Version: v3.0.7.0  
Product Version:v3.0.7.0  

Applicable Cameras:
1. Dhyana 400BSI V3, 95 V2, 401D, Aries 16, FL 9BW/26BW
2. Other models are also compatible, but systematic testing has not been performed for these additional models. Some features may not work optimally or may have potential issues. Users experiencing any problems during use are encouraged to contact us.

New Features:
1. Support for upgraded Dhyana 400BSI V3, 95 V2, 401D cameras.
2. Added automatic exposure configuration for four new MIchrome models: MIchrome 5 Pro II, MIchrome 6 II, MIchrome 16 II, MIchrome 20 II.
3. Added task management and fan speed settings for FL 9BW.
4. For dynamic stitching, when mosaic memory usage exceeds remaining memory, a high memory usage warning will appear (only once per stitching session). Added a save button to allow saving the current stitched image to prevent loss due to insufficient memory.
5. New feature: Warning for fogging risk when FL 9BW or 26BW temperature settings are below -25°C.
6. Compatibility with new firmware for MIchrome 20’s automatic exposure configuration.
7. Compatibility with FL 26BW, added low noise mode with three resolution settings.
8. Compatibility with fourth-generation HD Lite.
9. Modified the automatic exposure maximum gain range for MIchrome 20BW to [1, 240].
10. Added language selection and license agreement interface to the installer.
11. In the Line Profile module during camera preview, data curves now refresh with the image.
12. Added support for the new TrueChrome AF III camera.
13. Measurement function: Added a vertical line segment at the center of the double-arrow line graphic.

Bug Fixes:
1. Fixed the issue where the static and dynamic histograms could not manually input the right color levels.
2. Fixed mismatch between automatic and manual histogram color levels in static histograms.
3. Fixed issue with dynamic stitching causing forced exit on 8GB memory, preventing stitching of large images.
4. Added missing files to installer: msvcp140.dll, vcruntime140.dll, concrt140.dll.
5. Fixed issues with the gain list not displaying and trigger list errors on Dhyana 4040 (first generation).
6. Fixed fan settings for Dhyana XF/XV4040BSI. In the 4040 series CL mode, the fan only has on/off functionality; in USB mode, Dhyana XF4040BSI only has on/off functionality; other cameras have fan speed settings. XV series cameras do not have fans, so fan controls are not displayed.
7. Fixed issue with text graphics in measurement module where input text could not be edited, and real-time input characters were not visible. Solution: The text editing dialog now supports text copy, paste, cut, and proper display of input methods.
8. Fixed issue where image stitching could only be scaled down to 12.5%, not showing the full image. Modified strategy to calculate the minimum scale ratio dynamically based on a minimum width and height of 256 pixels. If the minimum ratio is greater than 12.5%, the ratio will be set to 12.5%.
9. Fixed the issue with MP4 and WMA video recording functions being greyed out and disabled on MIchrome 16 and MIchrome 20.
10. Fixed the issue where switching bit depth on MIchrome 5 Pro affected exposure time.
11. Fixed the issue on MIchrome 20BW where ROI followed by Binning and multiple clicks on the 90° function button caused screen lag. ROI, arbitrary binning, and rotation cannot be used simultaneously; any two can be used together, but enabling two disables the third.
12. Fixed issue where after loading default parameter set post-ROI, the screen would briefly turn white before returning to normal.
13. Fixed gain jump issue when adjusting exposure using the right arrow key with exposure priority enabled in automatic exposure on MIchrome 20BW.
14. Fixed bug where video recording did not automatically stop under To RAM mode due to limited memory. When To RAM is selected, automatic stopping should be enabled by default.
15. Fixed issue with color shift to red under halogen lighting on GT 2.0/5.0/12.
16. Fixed issue where switching between cameras with the same name and serial number did not take effect.
17. Fixed bug where RAM was checked but auto-stop was not checked on first startup after software installation.
18. Fixed progress bar anomaly when recording video with total time selected in memory.
19. Fixed issue with file format when saving ROI analysis CSV files with system hidden extensions.
20. Fixed issue where setting the capture time less than the frame period caused image capture failure without a prompt.
21. Fixed issue where changing magnification or calibration scale caused measurement graphics data to not refresh in static preview.
22. Fixed issue where editing file names in the acquisition module with the cursor in the middle of the string would move the cursor to the end of the string after writing a character.
23. Fixed issues with TrueChrome AF III: histogram adjustment having no effect; grayscale checkbox causing screen anomalies; image capture and video recording crashes; ROI functionality becoming usable when clicking on white balance default options; C-Mount checkbox causing focus position not to reset to 0.
24. Fixed issue with Dhyana 400BSI V3 where hard trigger signals did not show histogram data and CL mode light commands were ineffective.
25. Fixed issue where the first frame was not displayed in trigger mode.
26. Fixed issue with deviation in linear analysis lines or rectangles after switching ROI; now deleting linear analysis graphics clears the analysis curve.
27. Fixed issue with FL-20BW where soft trigger image capture failed.
28. Fixed issue where after restarting software post-ROI and canceling ROI, the focus box could not be moved to full screen.
29. Default gamma value changed to 23, default contrast value changed to 9, maximum exposure time set to 5s, applicable only to TrueChrome AF III cameras.
30. Fixed issue where the cursor in Line Profile analysis changed to a mouse arrow after switching cameras.
31. Fixed issue in manual counter where selecting multiple categories and deleting would only delete one category, not all selected categories.
32. Replaced TUCam.dll to fix issues with automatic exposure and gain priority where sliding the exposure time slider did not refresh the text box and exposure time settings did not take effect.